Environment (Air & Light)

Automatic Weather Station

WatchDog 2000 Series Weather Stations

» Full-featured weather stations measure temperature, humidity, rain, wind and solar radiation (varies by model)

» Customize your station with plug-in sensors to meet your needs

» Accurate, real-time weather information directly from your orchard or vineyard

» Log your data in fail-safe, non-volatile memory

» Choose measurement intervals from 1 to 60 minutes (holds 183 days of data with a 30 minute interval)

» Use the LCD Display to check current and daily high/low readings without a PC

» 12-month battery power with 4 AA lithium batteries.

» Communicate via wireless, cellular, shuttle, or direct connect (Optional )

For more details Click Here


Quantum /Light Meter

Quantum(PAR) Sensor / Meter /Datalogger

» Research grade measurement of photosynthetically active radiation (PAR), PPF, and PPFD

» Apogee Instruments Quantum sensors are a trusted standard for measuring PAR by agricultural professionals all over the world.

» PPFD measurements over plant canopies in outdoor environments, greenhouses, and growth chambers, and reflected or under canopy (transmitted) PPFD measurements in the same environments. 

» On-Spot Monitoring: Sensors with Meter, Sensor with USB output with memory

» Long time monitoring: Sensors compatible with external Data-Logger, Sensor with Apogee MicroCache Bluetooth Logger; Sensor with USB output & storage facility

» For all range of Quantum Sensor: https://www.apogeeinstruments.com/quantum

» Full-spectrum Quantum Sensor and with Meter: https://www.apogeeinstruments.com/full-spectrum-quantum-sensor

» Original Quantum Sensor: https://www.apogeeinstruments.com/original-quantum-sensor


Red - Far-red and unique PAR-FAR sensors

Red - Far-red and unique PAR-FAR sensors

» Apogee's new research-grade Red - Far-red and unique PAR-FAR sensors are excellent, cost-effective tools for measuring the output of plant lights for photobiology and plant morphogenic studies.

» The red - far-red sensor has a spectral range of 645 to 665 nm ± 5 nm (red) and 720 to 740 nm ± 5 nm (far-red). https://www.apogeeinstruments.com/red-far-red-sensor

» The PAR-FAR sensor has a spectral range of 400 to 700 nm ± 5 nm (PAR) and 702 to 761 nm ± 5 nm (Far-red). https://www.apogeeinstruments.com/par-far-sensors/

» See all Sensor and package: https://www.apogeeinstruments.com/red-far-red-and-par-far-sensors


Spectroradiometer

Portable Spectroradiometer Model PS Model PS-100/ PS-200 / PS-300

» Measures radiation spectra in relative, energy (Watts), or quantity units (moles) and reflected and transmitted spectra

» Non destructive measurement of irradiance/reflectance measurement of individual & Whole Plant or a field.

» Wavelength Range : 300 to 1100 nm,

» For the application of plant monitoring for the Chlorophyll, NDVI, Drought, Disease, Nutrient Stress, water stress, insect attack, and overall plant health (which is a vital aspect of successful agricultural operations)

» Full spectrum UV-VIS-NIR measurements, Ruggedized fiber-optic spectroradiometers

For more details Click Here


Plant Growth Microstation

WatchDog Plant Growth Micro Station Model 3684PAR1

» LCD displays current sensor readings and battery level

» Log 10,584 intervals (220 days at 30 minute intervals with 12-month battery life

» Data is stored in fail-safe non-volatile memory

» Water-resistant case

» Including Air Temp. , Relative Humidity and PAR Light and radiation shield

For more details Click Here


Pyranometer

Pyranometer (Sensors with Meter /Sensor for Datalogger)

» Apogee offers two types of pyranometers; our original silicon-cell models and our new line of thermopile pyranometers, both of which are now ISO 9060:2018 Class C rated (previously known as second class). Silicon-cell solar radiation sensor models are excellent for applications that do not require the higher accuracy and cost of a thermopile pyranometer. They are less expensive and have a faster response time, but have higher errors under cloudy conditions. Our new cost-effective thermopile pyranometers features a blackbody thermopile detector that provides a much broader and more uniform spectral response for better performance in all atmospheric conditions that compares favourably to other thermopile pyranometers at a fraction of the cost.

» Applications include shortwave radiation measurement in agricultural, ecological, and hydrological weather networks, measurement of global solar radiation, and optimizing photovoltaic systems.

» Sensor with Meter(On-Spot Monitoring): Sensors with Meter, Sensor with USB output & storage facility
Sensors (Long time monitoring): Sensors compatible with external Data-Logger, Sensor with Apogee MicroCache Bluetooth Logger; Sensor with USB output & storage facility

» Silicon-cell Pyranometer: https://www.apogeeinstruments.com/silicon-cell-pyranometers

» Thermopile Pyranometer: https://www.apogeeinstruments.com/thermopile-pyranometers

» For all range of Pyranometer : https://www.apogeeinstruments.com/pyranometer


Net Radiometer

Net Radiometer Model SN 500

» Four-component measurement of net radiation with black-body pyranometers and pyrgeometers.

» Consisting of a blackbody pyranometer and pyrgeometer pair that face upward to provide incoming shortwave and longwave radiation measurements and a complementary pair that face downward to provide outgoing shortwave and longwave radiation measurements. Individual sensors measure the four separate components of net radiation for best accuracy.

» Key Features : Measurement Range : 0 to 2000 Wm-2; Digital Output, Compact and Light Weight, Heated Sensors, Accurate and Affordable, Four year warranty

» Spectral Range: 385 – 2105nm (upward-looking), 295 – 2685nm (downward-looking)

For more details Click Here


Infrared Radiometer(IR-Meter)

Infrared Radiometer(IR-Meter)

» High accuracy, non-contact surface temperature measurement in harsh environmental conditions

» Plant canopy temperature measurement for use in plant water status estimation, phenotyping, phenomics and terrestrial surface (soil, vegetation, water, snow) temperature measurement in energy balance studies.

» Available with 4 FOV(Field of View) for on-spot monitoring(Sensor with Meter) / long time monitoring (Sensor compatible with Datalogger)

For more details Click Here


NDVI & PRI Sensor/Meter

NDVI Sensor(Downward-Looking) Model S2-112-SS

» The NDVI Sensors have the spectral ranges of 650 nm with 10 nm full-width half-maximum (Red) and 810 nm with 10 nm full-width half-maximum (NIR).

» Designed to use in field condition for on-spot measurements (through any Android Mobile) or long term monitoring through Bluetooth logger

» Self-powered NDVI sensor with 1% repeatability, < 1 %Long-term Drift,

» Field of View: 400, IP68 Rating, operating temp.: -40 to 70 C; 0 to 100 % RH

For more details Click Here

PRI Sensor (Downward-Looking) Model S2-122-SS

» The PRI Sensors have the spectral ranges of 532 nm with 10 nm full-width half-maximum (Green) and 570 nm with 10 nm full-width half-maximum (Yellow).

» Designed to use in field condition for on-spot measurements (through any Android Mobile) or long term monitoring through Bluetooth logger

» Self-powered PRI sensor with 1% repeatability, < 1 %Long-term Drift,

» Field of View: 400, IP68 Rating, operating temp.: -40 to 70 C; 0 to 100 % RH

For more details Click Here

Bluetooth Logger Model microCache Logger(AT-100)

» Designed to use in filed and long term operation

» IP67 Rated Logger can store up to 400,000 Entries

» Averaging Interval: 1-60 minutes, Sampling Interval: ≥ 1 second

» Inbuilt 2/3 AA 3.6 Volt Lithium Battery for long term operation in filed

» Bluetooth range : up to 45m

For more details Click Here


Oxygen Sensors

Oxygen Sensors /with Meter Model MO 200 and SO Series

» Reliable gaseous oxygen measurement in the laboratory and porous media.

» Apogee Instruments' oxygen sensors reliably measure 0 to 100% gaseous O2.

» Oxygen Sensor is available with Meter (for quick measurements)/compatible with Datalogger (For long term monitoring)

» Oxygen Sensors all Models : https://www.apogeeinstruments.com/oxygensensor

» Oxygen Sensors with Meter Model MO 200 : https://www.apogeeinstruments.com/mo-200-oxygen-sensor-with-handheld-meter


UV Sensors

UV-A Sensors NEW

» Measure total radiation from 300 to 400 nm

» Apogee Instruments' ultraviolet (UV-A) sensor provides a cost effective measurement of UV-A radiation.

» Measurement Units: Calibration factors for photon flux density units [µmol m-2 s-1] and energy flux density [W m-2] are provided with each sensor allowing for rapid unit conversions.

» Sensor with Meter Model MU 250 and Sensors (Compatible with logger) Model SU 200 Series

For more details Click Here


Logger

microCache Bluetooth® Micro Logger Model AT-100

» The new Apogee microCache (µCache) is a rugged(IP67 Rated), battery-powered, Bluetooth® Low Energy(Bluetooth range : 45m), single-sensor datalogger that works with several of Apogee's sensors.

» When used as a wireless field-logging device, the unit can store 9 months (Over 400,000 entries) of 1-minute data using the internal battery.

» Data can be viewed on your mobile device using the free Apogee Connect app for iOS and Android devices, with a Wi-Fi gateway coming soon

» Apogee Connect features live meter mode, real-time graphing, and the ability to send datasets to your computer.

» Compatible with Multiple Apogee Sensors : Currently connects with the SQ-110 Original Quantum, SQ-500 Full-spectrum Quantum, SQ-620 Extended Range PFD sensor, SQ-640 Quantum Light Pollution sensor, SP-700 Albedometer, S2-141 PAR-FAR sensor, S2-131 Red - Far-red sensor, SP-110 Silicon-cell Pyranometer, SP-510-SS and SP-610-SS Thermopile Pyranometers, SU-200 UV-A sensor, and SI-100 Series Infrared Radiometers, S2-112-SS NDVI Sensor, S2-122-SS PRI Sensor... More sensors coming soon!

For more details Click Here